Gas warning technology
Delve into the world of safety technology with our high-end OPP-SOR® CO and gas warning systems. From underground garage monitoring to gas warning systems, we offer reliable solutions for all your needs.
EBR-01 Einbaurahmen
Car parks and tunnels
for TGÜ-BM 3.6 incl. installation material and 1.50 m data cable.
Installation frame for split mounting of the
TGÜ-BM 3.6 on the control cabinet rear wall and
the operating and display unit in the control
cabinet door. Please observe the installation
instructions in data sheet 34120.
Installation frame for split mounting of the
TGÜ-BM 3.6 on the control cabinet rear wall and
the operating and display unit in the control
cabinet door. Please observe the installation
instructions in data sheet 34120.
GMF 2.E.CL2.01
Gas warning systems
Gasmessfühler für Chlor, Messbereich 0 bis 5 ppm
Im Aluminiumgehäuse,
Montage am Boden.
MAK-Wert: 0,5 ppm, Messbereich: 0-5 ppm.
Relative Gasdichte: 2,45.
Messprinzip: elektrochemisch.
Ausgang: 4-20mA, linear,
temperaturkompensiert, dadurch hohe Genauigkeit.
Niedrige Querempfindlichkeit auf andere Gase.
Gaszutritt über Sinterfilter.
Farbe: blau, Abm.: 90x80x80mm (BxHxT),
Schutzart: IP 44.
Datenblatt-Nr. 37401
ACHTUNG: Inbetriebnahme und Wartung dieses Gasmessfühlers ist nur durch
Fachpersonal von Oppermann Regelgeräte GmbH und
ausschliesslich im Gebiet der Bundesrepublik Deutschland möglich!
Im Aluminiumgehäuse,
Montage am Boden.
MAK-Wert: 0,5 ppm, Messbereich: 0-5 ppm.
Relative Gasdichte: 2,45.
Messprinzip: elektrochemisch.
Ausgang: 4-20mA, linear,
temperaturkompensiert, dadurch hohe Genauigkeit.
Niedrige Querempfindlichkeit auf andere Gase.
Gaszutritt über Sinterfilter.
Farbe: blau, Abm.: 90x80x80mm (BxHxT),
Schutzart: IP 44.
Datenblatt-Nr. 37401
ACHTUNG: Inbetriebnahme und Wartung dieses Gasmessfühlers ist nur durch
Fachpersonal von Oppermann Regelgeräte GmbH und
ausschliesslich im Gebiet der Bundesrepublik Deutschland möglich!
GMF 2.IR.CO2.09
Gas warning systems
Gasmessfühler für Kohlendioxid mit Infrarotmesszelle, Messbereich 0 bis 3000 ppm
Gehäuse aus Aluminium, Schutzart IP 65
Abm. 130 x 100 x 80 mm (LxBxH)
Ausgangssignal: 4-20 mA, linear
Messprinzip:Infrarotlichtabsorbtion, 2 Wellenlängen
temperaturkompensiert
Messbereich: 0 - 0,3 Vol.% (3000 ppm)
Messgenauigkeit: +/- 1% vom Messbereich
Gaszutritt: Diffusion
Filter: hydrophobe Teflonmembran
Spannungsversorgung: 12,5 - 36 V DC
Temperaturbereich: -20...+50°C
Druckbereich: 700-1300 hPa
frühere Artikelbezeichnung: GMF 770 IR CO2
Datenblatt-Nr. 37760
ACHTUNG: Inbetriebnahme und Wartung dieses Gasmessfühlers ist nur durch
Fachpersonal von Oppermann Regelgeräte GmbH und
ausschliesslich im Gebiet der Bundesrepublik Deutschland möglich!
Gehäuse aus Aluminium, Schutzart IP 65
Abm. 130 x 100 x 80 mm (LxBxH)
Ausgangssignal: 4-20 mA, linear
Messprinzip:Infrarotlichtabsorbtion, 2 Wellenlängen
temperaturkompensiert
Messbereich: 0 - 0,3 Vol.% (3000 ppm)
Messgenauigkeit: +/- 1% vom Messbereich
Gaszutritt: Diffusion
Filter: hydrophobe Teflonmembran
Spannungsversorgung: 12,5 - 36 V DC
Temperaturbereich: -20...+50°C
Druckbereich: 700-1300 hPa
frühere Artikelbezeichnung: GMF 770 IR CO2
Datenblatt-Nr. 37760
ACHTUNG: Inbetriebnahme und Wartung dieses Gasmessfühlers ist nur durch
Fachpersonal von Oppermann Regelgeräte GmbH und
ausschliesslich im Gebiet der Bundesrepublik Deutschland möglich!
GMF 4.E.CO.08
Gas warning systems
Gas measuring sensor for carbon monoxide, measuring range 0 – 300 ppm
Mounting approx. 1.5 – 1.8 m above the ground. MAC
value: 30 ppm, measuring range: 0 – 300 ppm,
relative gas density: 0.97. Measuring principle:
electrochemical, output: 4 – 20 mA, temperature
and humidity compensated to provide high accuracy
and low cross sensitivity to CO2, NO, NO2 and
H2O, gas inlet via sinter filter, aluminum
housing Dimensions: 125 x 80 x 57 mm (W x H x D),
protection class: IP 44 former article
designation GMF 401 CO 08
Data sheet no. 37110
Mounting approx. 1.5 – 1.8 m above the ground. MAC
value: 30 ppm, measuring range: 0 – 300 ppm,
relative gas density: 0.97. Measuring principle:
electrochemical, output: 4 – 20 mA, temperature
and humidity compensated to provide high accuracy
and low cross sensitivity to CO2, NO, NO2 and
H2O, gas inlet via sinter filter, aluminum
housing Dimensions: 125 x 80 x 57 mm (W x H x D),
protection class: IP 44 former article
designation GMF 401 CO 08
Data sheet no. 37110
GMF 4.IR.CH4.30.MOD
Gas warning systems
Gas measuring sensor CH4, measuring range 0 – 100% LEL, bus-compatible.
OPP-SOR Infrared gas measuring sensor,
bus-compatible, in an aluminum housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature -10 – 40 °C.
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 80 x 57 mm (L x W x D), color gray,
protection class: IP 54. Mounting under the
ceiling. Relative gas density: 0.55.
Data sheet no. 38109
OPP-SOR Infrared gas measuring sensor,
bus-compatible, in an aluminum housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature -10 – 40 °C.
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 80 x 57 mm (L x W x D), color gray,
protection class: IP 54. Mounting under the
ceiling. Relative gas density: 0.55.
Data sheet no. 38109
GMF 4.IR.CO2.18.HP-MOD
Gas warning systems
Gas measuring sensor for carbon monoxide, measuring range 0 – 5,000 ppm, bus-compatible, with a horn
OPP-SOR Infrared gas measuring sensor,
bus-compatible, with built-in horn in the
aluminum housing. Board with 2 output relays for
horn & warning transparency. Measuring principle:
Infrared technology using a high-quality
dual-beam 2-beam process. Precise,
low-maintenance and with low cross-sensitivity.
Contamination, air pressure, temperature and
humidity compensated. Gas inlet via diffusion.
Bus topology RS 485, supply 24 VDC. Permissible
ambient temperature -20 – 40 °C. Humidity 0 – 95%
rH non-condensing. Dimensions: 125 x 80 x 57 mm
(L x W x D), color gray, protection class: IP 54.
Mounting on the floor. Relative gas density 1.52.
Data sheet no. 38111
OPP-SOR Infrared gas measuring sensor,
bus-compatible, with built-in horn in the
aluminum housing. Board with 2 output relays for
horn & warning transparency. Measuring principle:
Infrared technology using a high-quality
dual-beam 2-beam process. Precise,
low-maintenance and with low cross-sensitivity.
Contamination, air pressure, temperature and
humidity compensated. Gas inlet via diffusion.
Bus topology RS 485, supply 24 VDC. Permissible
ambient temperature -20 – 40 °C. Humidity 0 – 95%
rH non-condensing. Dimensions: 125 x 80 x 57 mm
(L x W x D), color gray, protection class: IP 54.
Mounting on the floor. Relative gas density 1.52.
Data sheet no. 38111
GMF 4DUO.E/P.CO/LPG.MOD
Car parks and tunnels
DUO-MOD double sensor for carbon monoxide and LPG, measuring range: CO 0 to 300 ppm, LPG 0 to 100 % LEL
Certified to DIN EN 50545-1 VDE 0400-80 (TÜV
Rheinland) for monitoring underground garages and
tunnels (only CO sensors). The DUO dual sensor
consists of the two gas measuring sensors CO-Mod
and LPG-Mod. Both sensors differ from the mod
single sensors in the housing designs. These are
designed in such a way that they can be mounted
in line underneath each other. The CO/LPG
measuring cell is suitable for measuring low
concentrations of carbon monoxide or LPG in the
air. Type of gas: Carbon monoxide CO measuring
range: 0 – 300 ppm MAC-value: 30 ppm, relative
gas density: 0.97. Type of gas: Propane gas
measuring range: 0 – 100 % LEL MAC value: 1,000
ppm, relative gas density: 1.56. Housing:
Aluminum gray, IP 44 protection. Dimensions (H x
W x D): 80 x 125 x 57 mm. Gas supply: diffusion.
Output signal: RS485 MOD. Power supply: 12 – 36 V
DC. Long-term drift: 1% per month. Linearity
error: < 2%. Temperature range: -10 °C – +40 °C.
Humidity range: non-condensing. Data sheet 38104
Certified to DIN EN 50545-1 VDE 0400-80 (TÜV
Rheinland) for monitoring underground garages and
tunnels (only CO sensors). The DUO dual sensor
consists of the two gas measuring sensors CO-Mod
and LPG-Mod. Both sensors differ from the mod
single sensors in the housing designs. These are
designed in such a way that they can be mounted
in line underneath each other. The CO/LPG
measuring cell is suitable for measuring low
concentrations of carbon monoxide or LPG in the
air. Type of gas: Carbon monoxide CO measuring
range: 0 – 300 ppm MAC-value: 30 ppm, relative
gas density: 0.97. Type of gas: Propane gas
measuring range: 0 – 100 % LEL MAC value: 1,000
ppm, relative gas density: 1.56. Housing:
Aluminum gray, IP 44 protection. Dimensions (H x
W x D): 80 x 125 x 57 mm. Gas supply: diffusion.
Output signal: RS485 MOD. Power supply: 12 – 36 V
DC. Long-term drift: 1% per month. Linearity
error: < 2%. Temperature range: -10 °C – +40 °C.
Humidity range: non-condensing. Data sheet 38104
GMF 5.E.CO.08.MOD
Gas warning systems
Gas measuring sensor for carbon monoxide, measuring range 0 – 300 ppm, bus-compatible
Certified to DIN EN 50545-1 VDE 0400-80 (TÜV
Rheinland) for monitoring underground garages and
tunnels. Mounting approx. 1.5 – 1.8 m above the
ground. MAC value: 30 ppm, measuring range: 0 –
300 ppm, relative gas density: 0.97. Measuring
principle: electrochemical. Temperature and
humidity compensated to provide high accuracy and
low cross-sensitivity to CO2, NO, NO2 and H2. Bus
topology RS 485. In a gray plastic housing.
Dimensions: 125 x 80 x 57 mm (W x H x D).
Protection class: IP 44.
Data sheet no. 38107
Certified to DIN EN 50545-1 VDE 0400-80 (TÜV
Rheinland) for monitoring underground garages and
tunnels. Mounting approx. 1.5 – 1.8 m above the
ground. MAC value: 30 ppm, measuring range: 0 –
300 ppm, relative gas density: 0.97. Measuring
principle: electrochemical. Temperature and
humidity compensated to provide high accuracy and
low cross-sensitivity to CO2, NO, NO2 and H2. Bus
topology RS 485. In a gray plastic housing.
Dimensions: 125 x 80 x 57 mm (W x H x D).
Protection class: IP 44.
Data sheet no. 38107
GMF 5.IR.CH4.30.MOD
Gas warning systems
Gas measuring sensor CH4, measuring range 0 – 100% LEL, bus-compatible.
OPP-SOR infrared gas measuring sensor,
bus-compatible, in a plastic housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature: -10 – 40 °C
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 90 x 60 mm (L x W x D), color gray,
protection class: IP 54, mounting under the
ceiling. Relative gas density: 0.55.
Data sheet no. 38110
OPP-SOR infrared gas measuring sensor,
bus-compatible, in a plastic housing. Board
including 2 output relays for horn & warning
transparency. Measuring principle: Infrared
technology using a high-quality dual-beam 2-beam
process. Precise, low-maintenance and with low
cross-sensitivity. Contamination, air pressure,
temperature and humidity compensated. Gas inlet
via diffusion. Bus topology RS 485, supply 24
VDC. Permissible ambient temperature: -10 – 40 °C
Humidity 0 – 95% rH non-condensing. Dimensions:
125 x 90 x 60 mm (L x W x D), color gray,
protection class: IP 54, mounting under the
ceiling. Relative gas density: 0.55.
Data sheet no. 38110